产品规格参数

  • 测量值

    CO, O2

  • 测量范围

    CO: 0 ... - 60 ppm / 0 ... 8,000 ppm
    O2: 0 ... - 25 vol. %

  • 环境温度

    Indoor: +5 °C ... +40 °C
    Can be expanded on the system side if necessary
    Indoor with cooling unit: +5 °C ... +50 °C
    Can be expanded on the system side if necessary
    Outdoor: –20 °C ... +50 °C
    Can be expanded on the system side if necessary



应用领域

The SFDS is a continuous measurement system for monitoring carbon monoxide and oxygen in applications with high dust content. The extractive measurement of the components CO and O2 enables early detection of smoldering fires and timely initiation of fire-fighting measures. The ATEX-certified system components allow for reliable monitoring in dust Ex areas (ATEX zones 21 and 22, optionally in zone 20). Unlike with optical systems that measure the surface, deeper-lying embers can also be detected.

  • Early detection of smoldering fires


Device properties:

  • Early CO detection through continuous monitoring

  • Application-specific gas sampling with integrated backflush

  • Measurement point switchover for up to four sampling points

  • Gas sampling using heated sample gas line for ATEX zones 21/22 and also gas sampling unit for ATEX zones 21/22 (gas sampling from zone 20 is possible upon request)

  • Setup of analyzer cabinet in Ex-free areas

  • Pre-configured complete system for easy commissioning

优势

  • Risk minimization thanks to early detection of smoldering fires – protects your capital equipment

  • Long system uptime thanks to high gas sampling quality due to integrated backflush

  • Uninterrupted gas sampling possible in ATEX zones 21 and 22 (gas sampling from Zone 20 is possible upon request)

  • Low operating costs due to long service and test gas intervals and low consumption

  • Cost efficient with only one analyzer for up to four sampling points

  • Industry-proven S700 analyzers are the heart of the system



  • 测量原理

    冷提取, NDIR 光谱学, 顺磁哑铃原理, 电化学电池

  • 测量值

    CO, O2

  • 测量范围

    CO: 0 ... - 60 ppm / 0 ... 8,000 ppm
    O2: 0 ... - 25 vol. %

  • 环境温度

    Indoor: +5 °C ... +40 °C
    Can be expanded on the system side if necessary
    Indoor with cooling unit: +5 °C ... +50 °C
    Can be expanded on the system side if necessary
    Outdoor: –20 °C ... +50 °C
    Can be expanded on the system side if necessary

  • 防护等级

    Indoor: IP54
    Can be expanded on the system side if necessary
    Indoor with cooling unit: IP34
    Can be expanded on the system side if necessary
    Outdoor with cooling unit: IP56
    Can be expanded on the system side if necessary

  • 防爆认证

    ATEX:
    Zone 21, IIIC, 120 °C
    Option: Zone 20
    Analyzer cabinet: Non-explosion-proof areas
    Gas sampling unit: Zone 21, IIIC, 100 °C
    Sample gas line: Zone 21, IIIC, 100 °C

  • 电气安全性

    CE认证


联系方式
公司名称
Endress+Hauser
联系人
e+h(先生)销售经理
Q Q
3658482785
电话
0755-29194959
手机
19925147015
公司地址
地址
广东省深圳市龙岗区平湖华南城
科达创仪表网-专业仪器仪表集成商-深圳市科达创科技有限公司温馨提示

本网页所展示的有关【E+H SFDS process gas analyzer】的信息/图片/参数等由的会员【Endress+Hauser】提供,由科达创仪表网-专业仪器仪表集成商-深圳市科达创科技有限公司会员【Endress+Hauser 】自行对信息/图片/参数等的真实性、准确性和合法性负责,本平台(本网站)仅提供展示服务,请谨慎交易,因交易而产生的法律关系及法律纠纷由您自行协商解决,本平台(本网站)对此不承担任何责任。您在本网页可以浏览【E+H SFDS process gas analyzer】有关的信息/图片/价格等及提供【E+H SFDS process gas analyzer】的商家公司简介、联系方式等信息。

在您的合法权益受到侵害时,请您致电19129530036 / 19925147015,我们将竭诚为您服务,感谢您对科达创仪表网-专业仪器仪表集成商-深圳市科达创科技有限公司的关注与支持!

科达创仪表网-专业仪器仪表集成商-深圳市科达创科技有限公司